1, the output peak power, 600Watt; rated output power 550Watt
2, the ambient temperature range -40  to + 60 ; operating temperature range (inverter internal) -40  to + 82 
3, the proposed use of the PV modules: 2 * 300W / Vmp> 34V / Voc <50V; minimum and maximum starting voltage 22-50V
4, the rated voltage range 120V Power: 80-160VAC; 220V Power: 180-260VAC
5, rated frequency range 57-62.5Hz
6power factor98%
7, the power transmission modes: reverse transmissionload priority communication modes
power line carrierdaily computer monitoring system monitoring of power generation monitoring software can 
simultaneously monitor multiple threads 6 Powerline collector, you can simultaneously monitor 600 invertersEach logger monitoring power
 line
 100 inverters, monitoring systems 
1, the output peak power, 600Watt; rated output power 550Watt
2, the ambient temperature range -40  to + 60 ; operating temperature range (inverter internal) -40  to + 82 
3, the proposed use of the PV modules: 2 * 300W / Vmp> 34V / Voc <50V; minimum and maximum starting voltage 22-50V
4, the rated voltage range 120V Power: 80-160VAC; 220V Power: 180-260VAC
5, rated frequency range 57-62.5Hz
6power factor98%
7, the power transmission modes: reverse transmissionload priority communication modespower line carrierdaily computer monitoring
 system monitoring of power generation 
monitoring software can simultaneously monitor multiple threads 6 Powerline collector,
collect points 6 threads simultaneously six Powerline real-time data acquisition
8, electromagnetic compatibility EN50081.part1 EN50082.part1; grid disturbance EN61000-3-2 Safety EN62109; grid detection DIN VDE 1026 UL1741; Certificates: CEC, CE certification of national patents
9waterproof rating IP65; Weight 1.53kg
10, size: (length × width × height) 289mm × 200mm × 38mm